QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 Details

Mammography uses special X-ray images to detect abnormal growths or changes in the breast tissue. Physicians obtain mammogram to check for early signs of breast cancer. Doctors suggest regular mammograms tests to find breast cancer early.
QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is a bilateral breast mammogram machine. While screening mammogram, the breast is X-rayed from top to bottom and from side to side. A diagnostic mammogram focuses in on a particular lump or area of abnormal tissue. Doctors review results and explain the next steps during a follow-up appointment based on the report.
Why to choose QualiMed Eros Series II Of Digital Mammogram QMCMGEO2?
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is trustworthy.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 offers high quality.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is using State of the art engineering.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is portable.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is Experts’ choice.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is ost-effective
QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is used to get mammograms. The medical uses are:
- Mammograms are performed as part of a regular physical exam to provide a baseline reference for future comparison or to evaluate any unusual changes in the breast.
- It is the best screening test for reducing the risk of dying from breast cancer
- Images from a mammogram can help find calcifications, or calcium deposits in breasts.
- A mammogram can help healthcare provider decide if a lump, growth, or change in your breast needs further testing.
- The mammogram is also used to look for lumps that are too small to be felt during a physical exam.
To get the accurate result and further treatment options, mammogram machines should be purchased from a trustworthy seller.
QualiMed is a trustworthy, world class, innovative, experts’ choice developer, manufacturer, and supplier of bilateral breast mammogram machine for healthcare professionals. QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is the product.
The benefits and features of QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 are:
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is an efficient Navigator DR Mammography MSLRX02
- Perfect environmental adaption makes it available for indoor and vehicle application for different intended use.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 provides user-friendly GUI(Graphic user interface) and can support various exposure mode
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 provides user-friendly Interface.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is simple and easy to operate
- This medical device provides fast transmission speed, comply with DICOM3.0 protocol and can achieve the seamless link with HIS. RIS. and PACS systems.
- QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 is a powerful tool for patient management, data gathering and image reconstruction, viewing and measuring, typesetting, printing, storage, provides rich aides for diagnosis
- In QualiMed Eros Series II Of Digital Mammogram QMCMGEO2, with special detector of a-Si for breast mammography, X-ray is transferred to electric signals directly without the additional process of transferring X-Ray to visible and then to electric signal. This eliminates the artifact due to scattering of X-Ray and guarantees the authenticity from the imaging mechanism and can really satisfy the requirements of breast mammography on details.
- With high DOE, QualiMed Eros Series II Of Digital Mammogram QMCMGEO2 can guarantee high resolution of image and meanwhile decrease irradiation dose.
Technical Details:
1 |
Mammography System |
|
Rating power:5000VA Integrated System (Generator Integrated within the main device) High voltage generator output: &ge100 kHz, 20 kV to 40 kV increment step: 1 kV High performance X-ray tube: Standard:Molybdenum Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) Optional:Tungsten Anode, Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) Support isocenter rotation function C-arm Rotation range: +180°~-135° Height range of breast support surface: 735mm-1315mm C-arm power-driven electrically, Dual side digital display Compression plate: flexible and multi-level smart Compression Spatial Resolution: >6 Lp/mm Detector type: Amorphous Silicon Detector Effective Imaging Area: 24*30cm Acquisition Station compatible with DICOM 3.0 Focal distance : 650mm Added filter: Mo / Rh Added filter Switch: Manual/Automatic X-ray Field adjustment: Manual Magnification factor: 1.5 Exposure mode: Manual / AEC Supply: 220V~,±10% Frequency: 50/60Hz±1Hz Max. power : 5000 VA N.W.: 240 Kg Compact design, minimum device height: < 1.1 m Packing Size: 121 X 94 X 145 CM |
2 |
High-Voltage Generator |
|
a) Frequency:&ge100KHz b) Tube voltage Range: 20 kV ~40 kV in 1 kV step c) Max Output: 4 kW d) Max tube voltage:40kV e) Max tube current: 140mA f) Max current time product: &ge630mAs g) Ripple: <4%.
|
3 |
X-Ray Tube |
|
Standard: Imported X-ray tube for Mammography Anode Type: Molybdenum Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) Permanent filtration: 0.5mmBe Max anode speed: 10000rpm/min Max tube voltage:40kV Max tube current: 35mA(small)/140mA(Large) Anode heating capacity: 300 kHu Optional: Imported X-ray tube for Mammography Anode Type: Tungsten Focal Spot Size: 0.1 mm (Small)/ 0.3 mm (Large) Permanent filtration:0.5mmBe Max anode speed: 10000rpm/min Max tube voltage:49kV Max tube current: 35mA(small)/140mA(Large) Anode heating capacity: 300 kHu |
4 |
Beam LimitingDevice |
|
Electric switch between Molybdenum or Tungsten added filter Adjustable X-ray field manually. Light field indicator is on automatically as compression plate moves down Light field indicator is off with delay as compression plate stops moving Off delay of light field indicator can be set via software. |
5 |
C-arm Assembly |
|
C-arm up-down and rotation movement controlled via C-arm control panel C-arm stops automatically at common mammographic position: CC, OBL and LAT Rotation angle of OBL position can be set via software Support table up-down range: 735mm(L)~1315mm(H) Rotation type of C-arm: isocenter rotation around the examined part Rotation range of C-arm: -135o~180o Distance between focal spot and image reception area:650mm Magnification factor:1.5 Device can be installed in the movable physical vehicle as max height of device is less than 110cm Local display panel on the both side of the stand can indicate rotation angle of C-arm For safer operation, emergency stop button is locate on the top of C-arm Duplex foot switch(2 pcs) provided. |
6 |
Compression Device |
|
Up-down movement : power-driven electrically Compression control: continuous activation by foot Compression mode: flexible and multi-level compression, automatic and manual decompression Compression plate travel range: 5~268mm Compression force: 0~200N Compression thickness: 5~268mm Size of compression plate: 24X30cm. |
7 |
Local Operation and Display |
|
Dual display with backlight on the both side Parameters displayed: rotation angle of C-arm compression thickness compression force KV mAs density focal spot selected exposure mode Added filter selected automatic decompression indication state indication failure alarming indication Control function: KV mAs density selection of focal spot selection of filter selection of mammographic mode selection of automatic decompression after exposure. |
8 |
Anti-scatter Grid |
|
Support movable grid Grid ratio: 5:1 Grid density: 41 L/cm Grid focal distance:65cm; Manually unload grid in magnification mode. |
9 |
Digital Image Detector |
|
Detector type: Amorphous Silicon Detector Material: Amorphous Silicon + CSI Min. pixel: 85µm Image Matrix Sizes: 2816×3528 pixels Effective Imaging Area: 24cm×30cm Image Reading Duration: <1.4s Interval Duration: <30s Spatial Resolution: 6 lp/mm MTF: 50% DQE: 65% (1 Lp/mm) Output Gray scale: 14 bits |
10 |
Acquisition Station |
|
Intel CPU frequency&ge2.4GHz,&ge 4 GB Memory, &ge500 GB HDD LCDDisplay Image Acquisition Software Image Detector Self-check and adjustment Patient Information and Image Management Auto Explore Control Acquisition of Explored Image Information Browsing and Searching of Image Measure the Distance, Angle, Space of Image and Mark The Selected Area Image Process after Acquisition: Black and white reverse, rotate and flip, zoom, local editing, enhancement, filtering noise, copies, abridged, etc. DICOM 3.0 Services (Print, Store, Query/Retrieve, CDRW, Scheduled Workflow and Patient Information Reconciliation) Automatic failure diagnosis, error code and message indication Exposure activation: exposure button Data backup and recovery. |
11 |
Automatic Exposure Control |
|
Automatically select imaging parameters according to the thickness of breast and density of tissue Integration detector Automatically position selection. Automatically kV, filter and mAs selection. |
12 |
Manuals |
|
User Manual Pre-Installation Manual |
Item |
Description |
1 |
High resolution medical image display |
|
Display Hardware: 5MP LCD Display at 2K x 2.5K
|
Efficient Navigator DR Mammography MSLRX02
Power Capacity |
5000VA |
Voltage |
220V~,±10% |
Frequency |
50/60Hz±1Hz |
Earth resistance |
&le0.6&Omega |
Item |
Temperature |
Humidity |
Atmosphere Pressure |
Shield Room |
15℃~35℃ |
30%~60% (No dewing) |
700hPa~1060hPa |
Operator Room |
10℃~40℃ |
20%~80% (No dewing) |