QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 Details

Mammogram machine is used to obtain mammogram, an X-ray image of the breast. Doctors use mammogram to check for early signs of breast cancer. Doctors suggest regular mammograms tests to find breast cancer early.
QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is a bilateral breast mammogram machine In a screening mammogram, the breast is X-rayed from top to bottom and from side to side. A diagnostic mammogram focuses in on a particular lump or area of abnormal tissue. Doctors review results and explain the next steps during a follow-up appointment based on the report.
Why to choose QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 ?
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is using State of the art engineering.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is world class.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is portable.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is Experts choice.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 offers high quality.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is trustworthy
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is cost-effective.
QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 have several medical uses. It is used to get mammograms.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 provides mammograms. They are performed as part of a regular physical exam to provide a baseline reference for future comparison or to evaluate any unusual changes in the breast.
- It is the best screening test for reducing the risk of dying from breast cancer.
- A mammogram can help find calcifications, or calcium depositsin breasts.
- A mammogram can help healthcare provider decide if a lump, growth, or change in your breast needs further testing.
- The mammogram is also used to look for lumps that are too small to be felt during a physical exam.
To get the accurate result and further treatment options, mammogram machines should be purchased from a trustworthy seller.
QualiMed is a trustworthy, world class, innovative, experts’ choice developer, manufacturer, and supplier of bilateral breast mammogram machine for healthcare professionals. QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is the product.
The benefits and features of QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 are:
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is safe.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4uses fixed-center rotation technology, different angle imaging without moving of patient.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is convenient.
- This medical device offers very compact mechanical design.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 offers more protection, less radiation based on auto-exposal patient technology.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is comfortable.
- QualiMed Eros Series IV Of Digital Mammogram Machine QMCMGEO4 is easy to operate.
Medsinglong brand MSL6800 digital mammography system cost
- Detector System (ANKE): Parameter
- Detector material : a-Si
- Detector size : 24cm×30 cm
- Pixel matrix : 4096×3072
- Spatial resolution : 6.49LP/mm
- A/D : 16bit
- Pixel size : 77um
- Time of image acquisition : ≤2s
High frequency and voltage Generator(SPELLMAN made in USA)
- Input voltage : AC220V/50Hz
- Maximum power : 5KW
- Maximum output voltage : 40KV
- Maximum output current : 160mA
- Maximum exposure time : 10000ms
X ray Tube components(IAE made in Italy)
- Size : 0.1mm/0.3mm
- Anode angle : 15°
- Positive martial : Mo
- Inherent filtration : 0.5mm Be
- Anode heat storage capacity : 225KJ(300KHU)
- Additional filtration: 0.03mm(Mo)/0.025mm(RH), 0.03mm(Mo)/0.3mm(AL) or 0.05mm(RH)/0.05mm(Ag)
Exposure System
- AEC(According to the thickness and the density of the breast, the compression automatically choose filtration materials and exposure
- Manual Exposure mode(Setting ;KV、mA、ms)
C-arm system
- C-arm lifting range : 770mm~1310mm
- C-arm rotation range : -180°~ +180°
- Tube rotation range : -30°~ +30°
- SID : 65cm
- Protection : at least 4 kinds
Collimator
- Control : Auto
- light : LED
- Size (light field) : 18*24cm、5*18cm
- Filtration material : Mo/Rh, Mo/AL or RH/Ag
Compression systems
- Compression mode : Auto/Manual
- Compression release : Manual/Auto
- Compression plate : Support all kinds of size
- Compression precision : ±20N
- Maximum range : 5~280mm
- Compression range : 0N~200N
- Pressure/thickness display mode : Digital
Workstation
- Patient Information Management
- Case management functions including patient information, checking and image management
- Standard DICOM3.0Worklist query service, can query and download information from HIS /PACS
- Image Acquisition
- Integrated X-ray generator control interface, can adjust X-ray generator parameters directly from the software
- Exposure(For high voltage generator and flat-panel detector linkage control, exposure, detection, image acquisition
- DICOM image generation (combination of image pixel, patient information, exposure information)
- The patient parameters preset of each placement
- AEC Functions
- Image preprocessing
- Real time adjustment of the wide window position
- Real time clip of ROI
- Real time of horizontal and vertical mirror, rotate function
- Image Processing
- Real-time display system status
- Window width and level and Gamma adjustment, multi-point LUT curve adjustments
- Positive and negative conversion, image scaling, flip, mirror, rotate, zoom display
- Original image display, full screen, histogram display, window adjustment
- Image smoothing, sharpening, noise reduction, edge extraction, tissue equalization
- Image annotation function
- Real time prompt system can store the number of images
- Display patient information/check information/equipment information, image information
- 1×1、1×2、2×2 varieties of display mode
- The navigation display of image preview for all the patient
- Image output
- Standard DICOM3.0 output laser camera, can easily select configured scheme (film size, layout) printing
- Standard DICOM3.0 archive service, can put the image file to the server, supports the background automatically sent
- Computer
- Hardware Quad-Core CPU 3.0GHz,Memory8.0GB,Hadrdisk 1T,DVD,LCD display
- Operation system Win7
- 5M mammary special display optional